DLNP JINR development successfully tested at Privolzhsky Research Medical University
The choice of the place was not random. Vladislav Shcheslavsky is working at PRMU. He is a respected specialist in the field of Fluorescence Lifetime Imaging Microscopy (FLIM). Confocal scanning microscope Carl Zeiss LSM 880 is installed at the university laboratory of bioimaging. The microscope features a femtosecond laser and special equipment for FLIM measurements. It is this configuration that allows comparing JINR development with benchmark equipment in real experimental conditions.
One of the key components of such systems is the TCSPC module (Time-Correlated Single Photon Counting). It provides high-precision measurement of time intervals between photon detection and synchronization pulses, allowing the reconstruction of fluorescence decay kinetics with picosecond time resolution.
Despite the widespread use of TCSPC in modern optical research, there are no domestic equivalents of such instruments. Existing commercial solutions, particularly those manufactured by Becker & Hickl GmbH, are prohibitively expensive, and their acquisition and maintenance can be complicated under current international restrictions.
A team of scientists and engineers from DLNP JINR has developed a proprietary system with similar functionality under topic 07-2-А002, “Development of systems for measuring deep tissue oxygenation using time-domain diffuse optics (TD-DO).” While originally designed for time-resolved diffuse optics applications, the system's capabilities allow it to be used in other fields requiring high-precision detection of the temporal characteristics of photon signals.
During a visit to PRMU, the developed system was connected to a Carl Zeiss LSM 880 confocal microscope and tested against a commercial module from Becker & Hickl GmbH. The measurements demonstrated good comparability between the results of the two systems, confirming the performance of the JINR development under real experimental conditions.
The obtained results open up prospects for the further improvement and practical implementation of the TCSPC system developed at JINR as an alternative to foreign commercial solutions.
The scope of application for such devices is not limited to fluorescence microscopy. TCSPC is widely used in time-resolved spectroscopy, studies of energy transfer processes in molecular systems, diffuse optics, and functional optical tomography, as well as in LiDAR systems based on single-photon detection. Thus, the DLNP JINR development can find applications in both biomedical research and fundamental and applied physics.